So while my unregulated phone/DSL company was waiting for the most economical time to repair their downed cable, I worked on the Bexley CTC (under control of the Train Director at Bexley Tower) design. And got far enough into it that I felt comfortable starting construction:

These interlockings are westbound-only, for the end of double track at D'Arcy Ave. and the west entrance to the yard just before the tunnel. Signals governing eastward movements through blocks 7, 9, 10 and 11 are at Bexley depot, west of the tunnel:

The easterly 'pole line' carries 3 circuits: occupancy indications for blocks 9 & 10 coming from the Bexley panel, and block 13 coming from East Bexley.
Between Bexley Enginehouse and D'Arcy Ave. there are 6 circuits: Occupancy for blocks 9, 10, 11 and 13, a circuit triggering Yellow from driver SD9e1 and a 'turnout reversed' from Bexley panel to control relay R9T1.
Let's consider D'Arcy Ave:
SD9e1 gets its Yellow input from Bexley Enginehouse. Red comes from Oc9 OR'ed with R9T1 'normal' (for eastbound moves). The diode keeps the turnout position from changing the state of Oc9 visible to other interlockings.
The top SPDT (transfer) contact on the relay does turnout position. When it's reversed, Oc11 is grounded (activated) preventing EB moves from taking the wrong track.
The second SPDT selects whether dwarf 9e2 gets + or - voltage, changing it from red to yellow.
I hope I've clarified things a bit, but I can try different words if these don't work. Once this is posted I'll get back to work on the Bexley Enginehouse interlocking and its yard exit dwarf signals.

These interlockings are westbound-only, for the end of double track at D'Arcy Ave. and the west entrance to the yard just before the tunnel. Signals governing eastward movements through blocks 7, 9, 10 and 11 are at Bexley depot, west of the tunnel:

The easterly 'pole line' carries 3 circuits: occupancy indications for blocks 9 & 10 coming from the Bexley panel, and block 13 coming from East Bexley.
Between Bexley Enginehouse and D'Arcy Ave. there are 6 circuits: Occupancy for blocks 9, 10, 11 and 13, a circuit triggering Yellow from driver SD9e1 and a 'turnout reversed' from Bexley panel to control relay R9T1.
Let's consider D'Arcy Ave:
SD9e1 gets its Yellow input from Bexley Enginehouse. Red comes from Oc9 OR'ed with R9T1 'normal' (for eastbound moves). The diode keeps the turnout position from changing the state of Oc9 visible to other interlockings.
The top SPDT (transfer) contact on the relay does turnout position. When it's reversed, Oc11 is grounded (activated) preventing EB moves from taking the wrong track.
The second SPDT selects whether dwarf 9e2 gets + or - voltage, changing it from red to yellow.
I hope I've clarified things a bit, but I can try different words if these don't work. Once this is posted I'll get back to work on the Bexley Enginehouse interlocking and its yard exit dwarf signals.